图片 7

提示错误,继续找到这个dll拷到exe旁

设置win sdk 8,提醒错误:管道正在被关闭。

visual studio 二零一一安装战败
补充:
log中有:
[1470:274C][2015-04-07T10:53:44]i000: MUX: ExecuteError: Package
(vs_devenv) failed: Error Message Id: 1406 ErrorMessage: Could not
write value devenv.exe to key \SOFTWARE\Microsoft\Internet
Explorer\Main\FeatureControl\FEATURE_BLOCK_CROSS_PROTOCOL_FILE_NAVIGATION.
Verify that you have sufficient access to that key, or contact your
support personnel.
[2E34:1A84][2015-04-07T10:53:45]e000: Error 0x80070643: Failed to
install MSI package.
[2E34:1A84][2015-04-07T10:53:45]e000: Error 0x80070643: Failed to
execute MSI package.
[1470:274C][2015-04-07T10:53:45]e000: Error 0x80070643: Failed to
configure per-machine MSI package.
提示小编未曾写入注册表\SOFTWARE\Microsoft\Internet
Explorer\Main\FeatureControl\FEATURE_BLOCK_CROSS_PROTOCOL_FILE_NAVIGATION的权杖,不过本人找不到那条注册表
图片 1

安装sql server 二〇〇九 报错等难点怎么解决

   难点1:安装sql server 二零一零Escort2,安装进程中提醒错误:此计算机上安装了 Microsoft Visual Studio 2008的早先时期版本。请在装置 SQL Server 2009 前将 Microsoft Visual Studio 2010进级到 SP1。

  在此以前我的Computer上实在装了vs二〇〇八,于是自身希图去下载二个SP1补丁包,风度翩翩看800多M的大大小小,本来安装那么些软件就早就很麻烦了,还得花时间下载,这有未有别的更加好的点子吧?其实很简短,只供给改一投注册表就能够,方法如下:

  消除情势:

  匡正注册表。

  运营注册表,将HKEY-Local-Machine/Software/Microsoft/DevDiv重命名就行。

  安装好后再将其改回。

  将SQL Server安装重回上一步,然后再点下一步,那一个难点就瓜熟蒂落肃清了。

  难题2:安装SQL二零一零,提示删除SQL贰零零柒Express工具的消逝情势

  在装置SQL二〇〇九的时候,提示要删减SQL二零零六EXPRESS工具,在网络找了多数资料,终于找到贰个相比较方便的不二等秘书技了,希望能协助我们。改良注册表:HKEY_LOCAL_MACHINE\Software\Microsoft\Microsoft
SQL Server\90\Tools\ShellSEM,将ShellSEM项重命名或删除就可以。

  不能够安装 SQL Server 二零零六 Management Studio Express

  故障现象:

  在windows7中一度设置好SQL Server 二〇〇八 Express
况兼已经安装好SP3,然后从微软官方网站下载SQL Server 二零零六 Management Studio
Express 安装,发以后装置进程中,没有增加 Management 工具那风流倜傥项。

  化解方法:

  先使用sql server2010安装宗旨(在起头菜单的microsoft sql server
2010里头有)的掩护功效,将express进级到全体高等服务的Express。再安装SQL
Server 2010 Management Studio
Express,那就足以窥见工具这一个选项。安装成功。

  别的提醒:

  在设置SQL Server 二零零六 Management Studio Express 时会现身”此程序存在已知包容性难题“ 的对话框。如若您鲜明自个儿生机勃勃度安装过 SP1
以上的文本,并已晋级到具有高端服务的express,那么毫不理会这些对话框,直接按
”运行程序“那一个开关。不会有此外难题。

  难题3、撤废不能安装SQL Server 二〇〇八 Management Studio Express的难题

  小编的sql server 2009 express是visual studio
二〇〇八自带的,所以自然它未有management studio
,自身下了三个设置,然则不能够安装SQL Server 二零零六 Management Studio
Express。提示未选拔成效。

  刚从互连网找到技术方案,本人测量检验通过,再度分享:

  VS二零零六自带的SQL Server是Express简化版的,要求到“SQL
Server安装大旨>维护>版本升级”,把它晋级成“具备高等服务的Express”(不慢就可做到)。再运维SQL
Server 二零一零 Management Studio Express安装包,随后会重新弹出SQL
Server安装主题,选用“安装>崭新SQL
Server独立安装或向现存安装增添效果”,接下去就能够增多Management
Studio了。

图片 2

  下边是对具有高等服务的express版本的部分介绍:

  具有高等服务的 SQL Server Express 拥有 SQL Server 二零零五 Express
艾德ition 中的全体功用,况且还兼具下列功用:

  依靠 SQL Server 2006 Management Studio Express (SSMSE)
那生龙活虎新的轻巧使用的图片管理工具,轻巧管理 SQL Server Express。

  对 SQL Server 表中纯字符数量发生全文查询。
全文查询能够富含词和短语,或许词或短语的五种形式。

  对地面关周密据运维 SQL Server Reporting Services 报表。

图片 3

  以后,允许management studio express安装文件,现身管理工科具选项了:

图片 4

  难题4、安装程序配置检查RebootRequiredCheck时失败,难点一蹴而就形式

  问题陈述:

  GlobalRules: 针对法规组“GlobalRules”的 SQL Server 二〇〇八安装程序配置检查

  RebootRequiredCheck

  检查是不是要求挂起计算机重新开动。挂起重新运营会导致安装程序失利。

  失败

  供给重新起动计算机。必得另行启航Computer工夫安装 SQL Server。

  此外检查都是“已由此”。

  消除办法:

  依然用改正注册表的格局

  1. 在起来->运维中输入regedit ;

  2. 找到
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\Session
Manager 位置 ;

  3. 将左边窗口中名叫PendingFileRenameOperations的项删除,然后确认 ;

  4. 重复启用安装或修复程序,就可以。

  难点5、SQL Server 二零一零装置战败:Error writing to
file:Microsoft.analysisServices.AdomdClient.dll.

  难题陈诉

  ==========

  SQL Server 二零零六 规范版安装在Windows Server 2010上功亏生机勃勃篑,错误为:

  Error writing to file:Microsoft.analysisServices.AdomdClient.dll.
Verify that you have access to that directory.

  故障每一个核实

  ==========

  依照错误日志,存在以下错误信息:

  1.在装置到Install_sql_common_core_Cpu32_Action : InstallFiles.
Copying new files时现身以下错误音讯:

  Error writing to file:Microsoft.analysisServices.AdomdClient.dll.
Verify that you have access to that directory.

  2.在安装到Install_SqlBrowser_Cpu32_Action时现身以下错误音讯:

  系统不能够从钦命的设施上读取(The system cannot read from the specified
device.)

  3.在Detail.txt中设有以下错误新闻:

  Bootstrap/Log/20110620_153155/Registry_SOFTWARE_Microsoft_MSSQLServer.reg_

  二零一二-06-20 16:07:03 Slp: 系统无法从钦命的装置上读取。

  2011-06-20 16:07:03 Slp: Watson bucket for Msi based failure has
been created

  2011-06-20 16:07:03 Slp: InstallPackage: MsiInstallProduct returned
the result code 30.

  2011-06-20 16:07:03 Slp: Retry-able MSI return code detected: 30

  2011-06-20 16:07:03 Slp: Prompting user if they want to retry this
action due to the following failure:

  2011-06-20 16:07:03 Slp: —————————————-

  2011-06-20 16:07:03 Slp: The following is an exception stack listing
the exceptions in outermost to innermost order

  2011-06-20 16:07:03 Slp: Inner exceptions are being indented

  2011-06-20 16:07:03 Slp:

  2011-06-20 16:07:03 Slp: Exception type:
Microsoft.SqlServer.Configuration.MsiExtension.MsiExtensionException

  2011-06-20 16:07:03 Slp: Message:

  贰零壹贰-06-20 16:07:03 Slp: SQL Server 安装程序在运维 Windows Installer
文件时相遇错误。

  2011-06-20 16:07:03 Slp:

  二零一三-06-20 16:07:03 Slp: Windows Installer 错误新闻:
系统不能从钦命的装置上读取。

  2011-06-20 16:07:03 Slp:

  2011-06-20 16:07:03 Slp: Windows Installer 文件:
N:/x86/setup/sqlbrowser.msi

  二〇一一-06-20 16:07:03 Slp: Windows Installer 日志文件: C:/Program
Files/Microsoft SQL Server/100/Setup
Bootstrap/Log/二〇一三0620_153155/SqlBrowser_Cpu32_1.log

  2011-06-20 16:07:03 Slp: Data:

  2011-06-20 16:07:03 Slp: DisableRetry = true

  2011-06-20 16:07:03 Slp: Inner exception type:
System.ComponentModel.Win32Exception

  2011-06-20 16:07:03 Slp: Message:

  二零一一-06-20 16:07:03 Slp: 系统不能够从钦赐的设施上读取。

  2011-06-20 16:07:03 Slp:

  2011-06-20 16:07:03 Slp: —————————————-

  2011-06-20 16:23:57 Slp: Error result: -2068643839

  2011-06-20 16:23:57 Slp: Result facility code: 1203

  2011-06-20 16:23:57 Slp: Result error code: 1

  2011-06-20 16:23:57 Slp: Sco: Attempting to create base registry key
HKEY_LOCAL_MACHINE, machine

  2011-06-20 16:23:57 Slp: Sco: Attempting to open registry subkey
Software/Microsoft/PCHealth/ErrorReporting/DW/Installed

  2011-06-20 16:23:57 Slp: Sco: Attempting to get registry value
DW0200

  2011-06-20 16:23:58 Slp: Submitted 5 of 5 failures to the Watson
data repository

  2011-06-20 16:24:05 Slp: Detected localization resources folder:
1033

  2011-06-20 16:24:05 Slp: Detected localization resources folder:
2052

  4.在SqlBrowser_Cpu32_1.log中存在以下错误信息:

  MSI (s) (30:D4) [16:05:48:937]: Note: 1: 1305 2:
N:/x86/setup/sqlbrowser.msi 3: 1117

  MSI (s) (30:10) [16:07:03:656]: I/O on thread 2992 could not be
cancelled. Error: 1168

  MSI (s) (30:10) [16:07:03:656]: I/O on thread 796 could not be
cancelled. Error: 1168

  MSI (s) (30:10) [16:07:03:656]: I/O on thread 2172 could not be
cancelled. Error: 1168

  MSI (s) (30:10) [16:07:03:656]: I/O on thread 3280 could not be
cancelled. Error: 1168

  MSI (s) (30:10) [16:07:03:656]: I/O on thread 3796 could not be
cancelled. Error: 1168

  MSI (s) (30:10) [16:07:03:656]: I/O on thread 812 could not be
cancelled. Error: 1168

  MSI (s) (30:D4) [16:07:03:656]: MainEngineThread is returning 30

  MSI (s) (30:10) [16:07:03:656]: No System Restore sequence number
for this installation.

  系统无法从钦点的设备上读取。

  出现上述错误可能是出于系统相当的小概从光驱中读取安装文件。恐怕有以下两种原因:

  1.光驱产生损坏

  2.装置光盘中的文件发出损坏。

  3.透过远间隔路线举办设置,並且不抱有足够的权力

  4.透过远程桌面实行安装

  杀绝办法

  ==========

  1.将光盘中的文件复制粘贴到地点(假若现身谬误,请从网址上海重机厂复获得科学完好的安装文件)

  2.在地头一贯设置而不使用远程安装

server 2009 报错等主题素材怎么消除难题1:安装sql server 贰零零捌 传祺2,安装进度中唤醒错误:此Computer上安装了
Microsoft Visual Studio 贰零壹零 的最早版…

微软是首先个发表了SHA-1弃用安顿,在2015年之后Windows和IE将不再信赖SHA-1证书。适逢其会大家厂家的数字签字也到期了,索性就再也申请了sha256和sha1的新数字证书,用来给产品具名。

win10下vs2016编写翻译的程序如何运维在win7等种类(不要求安装Redistributable),编写翻译系统透视pdf

这两天新写的顺序要做beta测验,在做紫灰版(免安装版)时相遇了难点,vs二〇一四做的等级次序本认为像早前的vs版本相近把msvcrXXX.dll还会有其它多少个运转时库都放到exe旁边就可以,然并卵。。。,在win7的测验机上还有大概会唤醒找不到那几个dll:api-ms-win-crt-runtime-l1-1-0.dll,如下图

图片 5

一而再三翻五次找到这么些dll拷到exe旁,坑爹的生龙活虎幕放生了,竟然提醒那么些dll格外——不能够稳固程序输入点ucrtbase.terminate。。。

图片 6

莫不是是本子不对,作者机器上是有多少个例外尺寸的api-ms-win-crt-runtime-l1-1-0.dll,都试了下,照旧特别,那就没处说理了。。。然后谷歌(Google)了下,都以说要装vs二〇一五Redistributable恐怕KB2999226的修改(Win10通用CRT,不是win10的,是别的win7等系统的更新用来扶助通用crt的主次),试着装了下Redistributable包竟然装到五成报未定义的乖谬(0x80240017)。。。O(≧口≦)O,并且那也违反了栗褐版的初志,继续研商吗。

新兴小心到api-ms-win-crt-runtime-l1-1-0.dll同目录下有一群api-xxx的dll,也许都以有挂钩的,几乎整个目录全体dll全都拷到exe旁了,竟然能够运行了
O(∩_∩)O

留意:小编用的是win10 sdk中的dll,具体目录在C:\Program Files
(x86)\Windows Kits\10\Redist\ucrt\DLLs\x86
  ,分裂机器目录大概略有不一致。除此以外笔者的主次是三十位,所以是x86文件夹的,假如是陆十八个人等能够用Windows
Kits\10\Redist\ucrt\DLLs下的应和文件夹的dll

 

留心生机勃勃看拷过去的dll中还可能有一个叫ucrtbase.dll,难道和入口点那四个报错有关联,删了后的确又报第二个截图的大谬不然了。。。好坑爹啊,为何人家都以报遗失dll,就你是报找不到入口点呢(况兼依然另贰个已存在的dll),害得作者纠葛了这么久,不管什么样终于找到制作vs二零一四主次浅紫蓝版的不易姿势了——除了未来的msvc运转时库的多少个dll外,还要把win10通用crt相关的三个dll都放到exe旁才得以。

 

后记:用procexp又看了下青莲版程序在win10机械上加载dll的列表,竟然未有api-xxx那堆dll,三个都并未有,看来那多少个dll确实只是用来其余系统运营win10通用crt程序的,win10自己因为做了原生扶持所以就无需加载那么些dll了。

 

方今新写的次序要做beta测验,在做桃红版(免安装…

查看安装log文件,犹如下错误:

图片 7
log文件如下:
2015-04-07T10:53:42]i000: MUX: ExecuteError: Package (vs_devenv)
failed: Error Message Id: 1406 ErrorMessage: Could not write value
devenv.exe to key \SOFTWARE\Microsoft\Internet
Explorer\Main\FeatureControl\FEATURE_BLOCK_CROSS_PROTOCOL_FILE_NAVIGATION.
Verify that you have sufficient access to that key, or contact your
support personnel.
[2E34:1A84][2015-04-07T10:53:43]e000: Error 0x80070643: Failed to
install MSI package.
[2E34:1A84][2015-04-07T10:53:43]e000: Error 0x80070643: Failed to
execute MSI package.
[1470:274C][2015-04-07T10:53:43]e000: Error 0x80070643: Failed to
configure per-machine MSI package.
[1470:274C][2015-04-07T10:53:43]i000: MUX: Installation size in
bytes for package: vs_devenv MaxAppDrive: 0 MaxSysDrive: 1675264
AppDrive: 0 SysDrive: 622592
[1470:274C][2015-04-07T10:53:43]i000: MUX: Return Code:0x80070643
Msi Messages:1406 Result Detail:0 Restart:None
[1470:274C][2015-04-07T10:53:44]i000: MUX: Unregistering and
registering msiexec.
[1470:274C][2015-04-07T10:53:44]i000: MUX: Executing Process:
Exe:C:\Windows\system32\msiexec.exe Arguments:/unreg
[1470:274C][2015-04-07T10:53:44]i000: MUX: Process exit code: 0
[1470:274C][2015-04-07T10:53:44]i000: MUX: Executing Process:
Exe:C:\Windows\system32\msiexec.exe Arguments:/regserver
[1470:274C][2015-04-07T10:53:44]i000: MUX: Process exit code: 0
[1470:274C][2015-04-07T10:53:44]i000: MUX: Retrying the package
again
[1470:274C][2015-04-07T10:53:44]w348: Application requested retry of
package: vs_devenv, encountered error: 0x80070643. Retrying…
[2E34:1A84][2015-04-07T10:53:44]i301: Applying execute package:
vs_devenv, action: Install, path: C:\ProgramData\Package
Cache{B6A0A174-33E0-3D42-92EA-547D318CB149}v12.0.21005\packages\vs_devenv\vs_devenv.msi,
arguments: ‘ MSIFASTINSTALL=”7″ VSEXTUI=”1″
VS7.3643236F_FC70_11D3_A536_0090278A1BB8=”c:\program files
\Microsoft Visual Studio 12.0″‘
[1470:274C][2015-04-07T10:53:44]i000: MUX: ExecuteError: Package
(vs_devenv) failed: Error Message Id: 1406 ErrorMessage: Could not
write value devenv.exe to key \SOFTWARE\Microsoft\Internet
Explorer\Main\FeatureControl\FEATURE_BLOCK_CROSS_PROTOCOL_FILE_NAVIGATION.
Verify that you have sufficient access to that key, or contact your
support personnel.
[2E34:1A84][2015-04-07T10:53:45]e000: Error 0x80070643: Failed to
install MSI package.
[2E34:1A84][2015-04-07T10:53:45]e000: Error 0x80070643: Failed to
execute MSI package.
[1470:274C][2015-04-07T10:53:45]e000: Error 0x80070643: Failed to
configure per-machine MSI package.
[1470:274C][2015-04-07T10:53:45]i000: MUX: Installation size in
bytes for package: vs_devenv MaxAppDrive: 0 MaxSysDrive: 69632
AppDrive: 0 SysDrive: 0
[1470:274C][2015-04-07T10:53:45]i000: MUX: Return Code:0x80070643
Msi Messages:1406 Result Detail:WriteRegistryValues Restart:None
[1470:274C][2015-04-07T10:53:45]i000: MUX: Set Result: Return
Code=-2147023293 (0x80070643), Error Message=1406, Result
Detail=WriteRegistryValues, Vital=True, Package Action=Install, Package
Id=vs_devenv

那会儿将要把用了连年的电动具名脚本改为支撑sha256和sha1双证书的格式。集团原选拔signcode.exe和SignTool.exe二种方法打开签名,个中signcode同盟其它找的signcode-pwd.exe工具和pvk+spc文件能够无需密码就能够达成签订协议(不在这文中详诉),SignTool是一直用pfx证书+密码来拓宽具名。于是分别搜索二种办法:

Error 0x800700e8: Failed to write message type to pipe.
Error 0x800700e8: Failed to write send message to pipe.
Error 0x800700e8: Failed to send
BURN_ELEVATION_MESSAGE_TYPE_EXECUTE_MSI_PACKAGE message to
per-machine process.
Error 0x800700e8: Failed to configure per-machine MSI package.

查阅signcode的文档发现,signcode的授命行-a是用来钦定数字具名的签字算法。试验了下,只支持sha1和md5,不支持sha256。所以此办法放任。

系统是win7 64,也有装Windows6.1-KB2670838-x64.msu 补丁。

再查阅SignTool的文档.aspx),协助/fd来钦命签字,试了md5、sha1、sha256均辅助,所以直接在原来签字代码上增添个/sa
/fd sha256
后如下:

发表评论

电子邮件地址不会被公开。 必填项已用*标注